{"id":63042,"date":"2018-11-26T09:00:06","date_gmt":"2018-11-26T07:00:06","guid":{"rendered":"https:\/\/cerveny.top-me.eu\/detstudio-2-0-introducing-a-new-version-part-4\/"},"modified":"2020-06-08T16:01:03","modified_gmt":"2020-06-08T14:01:03","slug":"detstudio-2-0-introducing-a-new-version-part-4","status":"publish","type":"post","link":"https:\/\/amit.webfusion.dev\/en\/detstudio-2-0-introducing-a-new-version-part-4\/","title":{"rendered":"DetStudio 2.0 \u2013 Introducing a new version (Part 4)"},"content":{"rendered":"<p>Alarm detection (described\u00a0<a href=\"https:\/\/amit.webfusion.dev\/en\/detstudio-2-0-introducing-a-new-version-part-3\/\">in the previous part<\/a> on news in DetStudio 2.0) is naturally related to subsequent alarm signalisation for the user \u2013 whether on a control system&#8217;s HMI or terminal, by means of a text message or other suitable means of communication.<\/p>\n<p><a href=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w8_modemSMS.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-6822 size-full\" src=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w8_modemSMS.png\" alt=\"Objekt ModemSMS (DetStudio 2.0)\" width=\"327\" height=\"300\" srcset=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/w8_modemSMS.png 327w, https:\/\/amit.webfusion.dev\/wp-content\/uploads\/w8_modemSMS-300x275.png 300w\" sizes=\"auto, (max-width: 327px) 100vw, 327px\" \/><\/a><br \/>\nTo signalise alarms using text messages, we use the object &#8220;ModemSMS&#8221; that significantly facilitates work with SMS in EsiDet. The <strong>object\u00a0 &#8220;ModemSMS&#8221; allows us to s<\/strong><strong>end and receive text messages without any\u00a0programming required<\/strong><strong>!<\/strong>\u00a0Again, everything is set up in a simple and well-arranged table with two tabs &#8211; incoming and outgoing text messages.<\/p>\n<p><a href=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w8_smssend.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-6824 size-large\" src=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w8_smssend-500x108.png\" alt=\"Tabulka SMS\" width=\"500\" height=\"108\" \/><\/a><br \/>\n<strong>Thanks to sharing texts from the Operation log, text defined directly for alarms can be used.<\/strong> Other types of text messages can either have texts defined directly or in variables type String. <strong>That allows us to easily assign required text, addressee number and flag to trigger the text message sending to e<\/strong><strong>ach text message<\/strong><strong>.<\/strong> The rest is left in the table that sends the text message. If the first text message sending fails, <strong>the table automatically repeats the attempt twice<\/strong>. And when you need to\u00a0<strong>send a text message to multiple telephone numbers at once<\/strong>? That&#8217;s no trouble for our table! Just put multiple numbers of addressees into the column that defines the number (you may do so directly or using a variable type String, or\u00a0using the property type NumberX).<\/p>\n<p><a href=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w8_smsparse.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-6823\" src=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w8_smsparse-500x96.png\" alt=\"\" width=\"500\" height=\"96\" \/><\/a><\/p>\n<p>We can define incoming text messages just as easily (into the table rows). Notice the columns &#8220;Platn\u00fd odes\u00edlatel&#8221; (Valid sender) and &#8220;Odpov\u011b\u010f&#8221; (Answer) in the images. These columns allow us <strong>to easily filter telephone numbers from which the station is allowed to receive text messages<\/strong>\u00a0and at the same time to <strong>define whether the station should send a reply\u00a0<\/strong>using the flag in the column &#8220;Odpov\u011b\u010f&#8221;\u00a0(Answer).<\/p>\n<p>Another innovation is certainly a wish come true for many of our customers. When programming a station with Ethernet interface, a global object called <strong>Ethernet <\/strong>is available that automatically informs us on the communication interface status and furthermore, it\u00a0<strong>performs automatic synchronisation of the station time with the time server on the Internet<\/strong>.<\/p>\n<p><a href=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w9_ethernetProp.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-6826\" src=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w9_ethernetProp.png\" alt=\"\" width=\"274\" height=\"421\" srcset=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/w9_ethernetProp.png 274w, https:\/\/amit.webfusion.dev\/wp-content\/uploads\/w9_ethernetProp-195x300.png 195w\" sizes=\"auto, (max-width: 274px) 100vw, 274px\" \/><\/a><\/p>\n<p>Many of you would surely welcome information on\u00a0<strong>whether Ethernet interface is connected into a LAN network<\/strong>, or <strong>whether it is possible to use Ethernet interface to communicate on the Internet<\/strong>.<\/p>\n<p><a href=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w9_ethernet.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-6825\" src=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/2018\/11\/w9_ethernet.png\" alt=\"\" width=\"412\" height=\"278\" srcset=\"https:\/\/amit.webfusion.dev\/wp-content\/uploads\/w9_ethernet.png 412w, https:\/\/amit.webfusion.dev\/wp-content\/uploads\/w9_ethernet-300x202.png 300w\" sizes=\"auto, (max-width: 412px) 100vw, 412px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Would you like to try out the new DetStudio version 2.0 right now?<\/strong> Contact our\u00a0<a href=\"https:\/\/amit.webfusion.dev\/en\/about-us\/technical-support\/\">technical support<\/a>.<\/p>\n<p><em>Stay tuned for the next part of our series on innovations in DetStudio 2.0<\/em><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Alarm detection (described\u00a0in the previous part on news in DetStudio 2.0) is naturally related to subsequent alarm signalisation for the user \u2013 whether on a control system&#8217;s HMI or terminal, by means of a text message or other suitable means of communication. To signalise alarms using text messages, we use the object &#8220;ModemSMS&#8221; that significantly [&hellip;]<\/p>\n","protected":false},"author":20,"featured_media":6627,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[150,151],"tags":[],"class_list":["post-63042","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-novinky","category-software"],"acf":[],"_links":{"self":[{"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/posts\/63042","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/comments?post=63042"}],"version-history":[{"count":0,"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/posts\/63042\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/media\/6627"}],"wp:attachment":[{"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/media?parent=63042"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/categories?post=63042"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/amit.webfusion.dev\/en\/wp-json\/wp\/v2\/tags?post=63042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}